Radiological and Functional Consequences of Open Reduction Internal Fixation with Locking Plate Versus Dynamic Condylar Screw in Type C1 Complete Articular Fracture of Distal Femur

Radiological and Functional Consequences of Open Reduction Internal Fixation with Locking Plate Versus Dynamic Condylar Screw in Type C1 Complete Articular Fracture of Distal Femur

Authors

  • Ali Raza Department of Orthopaedic Surgery, Mayo Hospital, Lahore
  • Shujauddin Department of Orthopaedic Surgery, Mayo Hospital, Lahore
  • Usman Khalid Kazi Department of Orthopaedic Surgery, Mayo Hospital, Lahore
  • Shahid Ali Department of Orthopaedic Surgery, Mayo Hospital, Lahore
  • Maryam Chaudhry
  • Muhammad Akram Department of Orthopaedic Surgery, Mayo Hospital, Lahore

DOI:

https://doi.org/10.21649/akemu.v30i2.4444

Keywords:

Keywords: distal shaft of the femur, closed fracture, locking plate, Dynamic condylar screw.

Abstract

Background: One of the body's main joints for bearing weight is the knee. Its issues are likewise difficult to resolve. Damage to this joint can cause abnormalities in the alignment, stability, and motion of the knee, which impairs function.

Objective: To compare the functional and radiological outcome in AO type C1 distal femur fractures fixed with locking plate versus dynamic condylar screw.

Methods: The study comprised 94 patients aged 18 to 60 years who had an isolated distal femur fracture and an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type C1 closed fracture. Patients with diabetes mellitus, chronic renal disease, chronic liver disease, ischemic heart disease, pathological fractures, head injuries with a Glasgow coma scale of less than 14, and malignancy were excluded from the sample. The patients were assigned by lottery to groups A and B. In groups A and B, they were treated with dynamic condylar screws (DCS) and locking plate fixation, respectively..

Results: Among 94 patients, 30 (63.8%) were men and 17 (36.2%) were women in Group A; similarly, 33 (70.2%) were men and 14 (29.8%) were women in Group B. Patients in group A had an average age of 38.8±6.19 years, whereas those in group B had an average age of 39.5±7.36 years. 02 patients (4.2%) in Group-A and 05 patients (10.6%) in Group-B experienced infection. The union rate was 45 (95.7%) in group A (locking plate fixation technique) and 40 (85.10%) in group B (dynamic condylar screw technique). 35 (74.46%) in group A, 08 (17.1%) in good, 03 (6.38%) in average, and 01 (2.1%) in poor; in group B, 25 (53.2%) in excellent, 09 (19.2%) in decent, and 10 (21.3%)  had average and 03(6.3%) had poor functional outcome.

Conclusion: In terms of clinical and radiological evaluation, the type C1 distal shaft femur fixation with locking plate performs better than the dynamic condylar screw, which has a lower infection rate and better union and functional success

References

Morshed S. Current options for determining fracture union. J. adv. med. 2014;2014(1):708574..

Agrawal A. Distal femur AO type A fractures – Surgical options, techniques, results and complications. Trauma Int. 2015;1(2):12-6.

Gururaj NG, Vinaya G, Ahmad R. Comparative study between Dynamic Condylar Screw and Locking Plate Fixation in fractures of distal femur in adults – A study of 30 cases. Indian J Orthop Surg. 2016;2(2):147-50.

Garra G, Singer AJ, Taira BR, Chohan J, Cardoz H, Chisena E, et al. Validation of Wong –Baker FACES pain rating scale in pediatric emergency department patients.AcadEmerg Med. 2010;17(1):50-4.

Shah SGM, Sahito B, Kumar D, Tariq SM, Parkh N, Ali M. Functional outcome of intraarticular and extraarticular distal femur fracture treated with distal femur locking plate. Rawal Med J 2018; 4(3): 694-7.

Ramana SSV, Vittal MPR. Study of Supracondylar Fractures of Femur by Various Modalities of Treatment. Journal of Dental and Medical Sciences 2015; 14(12):16-9.

Kumar GNK, Sharma G, Farooque K, Sharma V, Ratan RR, Yadav S et al. Locking Compression Plate in Distal Femoral Intra-Articular Fractures: Our Experience. Journal of Clinical & Experimental Orthopaedics 2019; 5(2): 1-7.

Myers P, Laboe P, Johnson KJ, Fredericks PD, Crichlow RJ, Maar DC, et al. Patient Mortality in Geriatric Distal Femur Fractures. J Orthop Trauma. 2018;32(3):111-115.

Malik I, Khan R, khurana R, Sharma S. Comparative study of management of distal femoral fractures managed by dynamic condylar screw and distal femoral locking compression plate. Webmed Central Orthop. 2015;6(9):WMC004976.

Jalili A, Bahrabadi M, Zare Sh. A comparison of locking versus nonlocking plates in distal femur fractures. Shafa Ortho J. 2014;1(3):17-21.

Loosen A, Fritz Y, Dietrich M. Surgical Treatment of Distal Femur Fractures in Geriatric Patients. Geriatr Orthop Surg Rehabil. 2019;10(1):2151459319860723.

Myers P, Laboe P, Johnson KJ, Fredericks PD, Crichlow RJ, Maar DC, et al. Patient Mortality in Geriatric Distal Femur Fractures. J Orthop Trauma. 2018;32(3):111-115.

Ali I, Shahabuddin. Surgical outcome of supracondylar and intercondylar fractures femur in adults treated with dynamic condylar screw. JPMI. 2011;2(1):49-55.

Adams AJ, Mahmoud MAH, Wells L, Flynn JM, Arkader A. Physeal fractures of the distal femur: does a lower threshold for surgery lead to better outcomes? J Pediatr Orthop B. 2020;29(1):40-46.

Morwood MP, Gebhart SS, Zamith N, Mir HR. Outcomes of fixation for periprosthetic tibia fractures around and below total knee arthroplasty. Injury. 2019;50(4):978-982.

Shields E, Behrend C, Bair J, Cram P, Kates S. Mortality and Financial Burden of Periprosthetic Fractures of the Femur. Geriatr Orthop Surg Rehabil. 2014;5(4):147-53.

Loosen A, Fritz Y, Dietrich M. Surgical Treatment of Distal Femur Fractures in Geriatric Patients. Geriatr Orthop Surg Rehabil. 2019;10(1):2151459319860723

Pennock AT, Ellis HB, Willimon SC, Wyatt C, Broida SE, Dennis MM, et al. Intra-articular Physeal Fractures of the Distal Femur: A Frequently Missed Diagnosis in Adolescent Athletes. Orthop J Sports Med. 2017;5(10):2325967117731567.

Morwood MP, Gebhart SS, Zamith N, Mir HR. Outcomes of fixation for periprosthetic tibia fractures around and below total knee arthroplasty. Injury. 2019;50(4):978-982

Dugan TR, Hubert MG, Siska PA, Pape HC, Tarkin IS. Open supracondylar femur fractures with bone loss in the polytraumatized patient - Timing is everything! Injury. 2013 ;44(12):1826-31.

Boyce RH, Singh K, Obremskey WT. Acute Management of Traumatic Knee Dislocations for the Generalist. J Am Acad Orthop Surg. 2015;23(12):761-8.

Nizegorodcew T, Palmieri G, Peruzzi M, Galli M. Allograft for the treatment of traumatic severe bone loss in the lateral femoral condyle: A case report. Injury. 2018;49(Suppl 4):S16-S20.

Pennock AT, Ellis HB, Willimon SC, Wyatt C, Broida SE, Dennis MM, et al. Intra-articular Physeal Fractures of the Distal Femur: A Frequently Missed Diagnosis in Adolescent Athletes. Orthop J Sports Med. 2017;5(10):2325967117731567.

Hoskins W, Sheehy R, Edwards ER, Hau RC, Bucknill A, Parsons N, et al. Nails or plates for fracture of the distal femur? data from the Victoria Orthopaedic Trauma Outcomes Registry. Bone Joint J. 2016;98-B(6):846-50.

McDonald TC, Lambert JJ, Hulick RM, Graves ML, Russell GV, Spitler CA, et al. Treatment of Distal Femur Fractures With the DePuy-Synthes Variable Angle Locking Compression Plate. J Orthop Trauma. 2019;33(9):432-437

Adams AJ, Mahmoud MAH, Wells L, Flynn JM, Arkader A. Physeal fractures of the distal femur: does a lower threshold for surgery lead to better outcomes? J Pediatr Orthop B. 2020;29(1):40-46.

Canadian Orthopaedic Trauma Society. Are Locking Constructs in Distal Femoral Fractures Always Best? A Prospective Multicenter Randomized Controlled Trial Comparing the Less Invasive Stabilization System With the Minimally Invasive Dynamic Condylar Screw System. J Orthop Trauma. 2016;30(1):e1-6.

Goodship AE, Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. BJJ. 1985;67(4):650-5.

Ricci WM, Streubel PN, Morshed S, Collinge CA, Nork SE, Gardner MJ. Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases. J Orthop Trauma. 2014;28(2):83-9.

Nowak J, Holgersson M, Larsson S. Sequelae from femur of shaft fractures are common: a prospective study of 222 patients. Acta Orthop. 2005;76(1):496–502.

Solanki R, Tolani A, Asati S, Kansara H, Pathria V. AO type C distal femur fracture: results of operative management in 52 patients. Int J Orthop Sci 2018;s 4(4):73-7.

Khajotia BL, Shekhawat V, Chauhan S, Bhatiwal S. Clinical and radiological outcome of distal femoral fractures treated by distal femoral locking compression plate. Int J Res Orthop. 2019;5(6):1083-7.

Surulivel VJ, Ganesan Ram Ganesan GR, Rajasekeran R.

Dynamic condylar screw versus supacondylar nail in the management of supracondylar fracture distal femur. Int Surg J. 2015;2(3):373-6.

Downloads

Published

06/29/2024

How to Cite

Raza, A., Shujauddin, Kazi, U. K., Shahid Ali, Chaudhry, M., & Muhammad Akram. (2024). Radiological and Functional Consequences of Open Reduction Internal Fixation with Locking Plate Versus Dynamic Condylar Screw in Type C1 Complete Articular Fracture of Distal Femur. Annals of King Edward Medical University, 30(2), 171–176. https://doi.org/10.21649/akemu.v30i2.4444

Issue

Section

Research Articles

Similar Articles

> >> 

You may also start an advanced similarity search for this article.

Loading...